Download Print this page

Gns Relay No Load; Gns Relay - Mahindra Quanto Ems Diagnostic Manual

Advertisement

DIAGNOSTIC MANUAL
QUANTO
P1712

GNS RELAY

GNS relay along with starter relay runs the starter motor.The GNS relay is controlled by EMS ECU.
NORMAL OPERATION
Ignition ON
No malfunction detected by EMS ECU in the control circuit of
GNS relay
DTC DETECTING CONDITIONS
Ignition ON
EMS ECU supply voltage 8-16V
Open circuit is detected in in the control circuit of GNS relay
DTC REACTIONS
Engine will not start
HEALING CONDITION
Ignition Off/On
The repair methods given by the manufacturer in this document are based on the technical specifications, current at the time of release. The methods may be modified as a result of changes introduced by the
manufacturer in the production of the various component units and accessories from which the vehicles are manufactured. The reproduction, translation, transmission, in part of or whole of the present document,
are prohibited without the prior written consent of Mahindra & Mahindra Ltd. The use of this document by any person other than the trained personnel, at the Authorized Service Centre of Mahindra & Mahindra Ltd.,
will amount to unauthorized use and shall be liable for penalty/prosecution© 2012 Mahindra & Mahindra Ltd.
EMS
DTC INFORMATION

GNS RELAY NO LOAD

PROBABLE CAUSES OF FAILURE
MAN-00201
SEP 2012/Rev 1
Open circuit in GNS relay
control wire
Faulty GNS relay
Faulty EMS ECU
`
315

Advertisement

loading