Download Print this page

Short Circuit In Bank 0 - Mahindra Quanto Ems Diagnostic Manual

Advertisement

DIAGNOSTIC MANUAL
QUANTO
P2146
INJECTORS
The injectors are solenoid actuated and controlled by EMS ECU. Both high and low side of the injectors
are controlled by EMS ECU. The EMS ECU measures the voltage drop through fixed resistors and
controls it.
NORMAL OPERATION
Ignition ON
The injector bank is checked while initialization and running
and found normal.
DTC DETECTING CONDITIONS
Ignition ON
EMS ECU supply voltage 8-16V
Short in injector bank
DTC REACTIONS
OBD check lamp continuously ON.
Engine Shuts OFF.
HEALING CONDITION
Ignition Off/On
The repair methods given by the manufacturer in this document are based on the technical specifications, current at the time of release. The methods may be modified as a result of changes introduced by the
manufacturer in the production of the various component units and accessories from which the vehicles are manufactured. The reproduction, translation, transmission, in part of or whole of the present document,
are prohibited without the prior written consent of Mahindra & Mahindra Ltd. The use of this document by any person other than the trained personnel, at the Authorized Service Centre of Mahindra & Mahindra Ltd.,
will amount to unauthorized use and shall be liable for penalty/prosecution© 2012 Mahindra & Mahindra Ltd.
EMS

SHORT CIRCUIT IN BANK 0

DTC INFORMATION
MAN-00201
SEP 2012/Rev 1
PROBABLE CAUSES OF FAILURE
Short in injector bank
Faulty Injectors
Faulty EMS ECU
`