Latched mode
Step 1
Press and hold torch trigger
Shielding gas is expelled (gas pre-flows)
Wire feed motor runs at "creep speed".
Arc ignites after the wire electrode makes contact with the workpiece; welding current flows.
Change over to pre-selected WF speed (main program P
Step 2
Release torch trigger (no effect)
Step 3
Press torch trigger (no effect)
Step 4
Release torch trigger
WF motor stops.
Arc is extinguished after the preselected wire burn-back time expires.
Gas post-flow time elapses.