KERN KDE-T Operating And Installation Instructions page 46

Display unit
Table of Contents

Advertisement

(example)
(example)
(example)
KDE-T-BA_IA-e-1210
„bASUnt" is displayed. This is where you can set the required
weighing unit.
Press
to change between the individual units and
to select the required unit (ex. here: „kg").
press
"SCL.CAP 1"will appear briefly.
Setting first range
A numeric value appears and the digit on the right is
flashing.
Press
to increase the numeric value or
decrease. Press
place.
Set weighing scale capacity (here is an example of 50 kg)
and press
to confirm.
"rESOLE 1"will appear briefly followed by a numeric value.
Set readability for first range. You can select between
default values that are dependent on the max load of the
weighing scale.
Press
to change between values.
Press
to confirm the required value.
"rESOLE 2"will appear briefly followed by a numeric value. As
above, enter required readability and press
the required value.
"F" will appear briefly before the weighing scale changes to
adjusting mode and "CAL" will be displayed.
Linearizing a weighing scale (see chap 6.7.1)
to change to a different decimal
to
to confirm
46