FIBARO WALLI FGWDSEU-221 Operating Manual page 27

Double switch
Hide thumbs Also See for WALLI FGWDSEU-221:
Table of Contents

Advertisement

33.
Description
Parameter size 4B
Default value
Available
values
34.
Description
Parameter size 4B
Default value
Available
values
Alarm configuration - 4th slot
This parameter determines to which alarm
frames and how the device should react. The
parameters consist of 4 bytes, three most sig-
nificant bytes are set according to the official
Z-Wave protocol specification.
[0x02, 0xFF, 0x00, 0x00]
(CO Alarm, any notification, no action)
1B [MSB] – Notification Type
2B – Notification Status
3B – Event/State Parameters
4B [LSB] – action:
0x00 – no action, 0xX1 – turn ON, 0xX2 – turn
OFF, 0xX3 – turn ON/OFF continuously, 0x0X
– no action on LED frame, 0x1X – LED frame
blinks red, 0x2X – LED frame blinks green,
0x4X – LED frame blinks blue, 0x8X – disable
LED frame, 0xFX – LED frame LAPD signal
(red-white-blue)
Alarm configuration - 5th slot
This parameter determines to which alarm
frames and how the device should react. The
parameters consist of 4 bytes, three most sig-
nificant bytes are set according to the official
Z-Wave protocol specification.
[0x04, 0xFF, 0x00, 0x00]
(Heat Alarm, any notification, no action)
1B [MSB] – Notification Type
2B – Notification Status
3B – Event/State Parameters
4B [LSB] – action:
0x00 – no action, 0xX1 – turn ON, 0xX2 – turn
OFF, 0xX3 – turn ON/OFF continuously, 0x0X
– no action on LED frame, 0x1X – LED frame
blinks red, 0x2X – LED frame blinks green,
0x4X – LED frame blinks blue, 0x8X – disable
LED frame, 0xFX – LED frame LAPD signal
(red-white-blue)
27