Buttons orientation
This parameter allows reversing the operation
of the buttons.
0
0 – default (1st button controls 1st channel, 2nd
button controls 2nd channel)
1 – reversed (1st button controls 2nd channel,
2nd button controls 1st channel)
Outputs orientation
Only in Double Switch Mode
This parameter allows reversing the operation
of Q1 and Q2 without changing the wiring (e.g.
in case of invalid connection). Changing orienta-
tion turns both outputs off.
0
0 – default (Q1 - 1st channel, Q2 - 2nd channel)
1 – reversed (Q1 - 2nd channel, Q2 - 1st channel)
Alarm configuration - 1st slot
This parameter determines to which alarm
frames and how the device should react. The
parameters consist of 4 bytes, three most sig-
nificant bytes are set according to the official
Z-Wave protocol specification.
[0x00, 0x00, 0x00, 0x00] (disabled)
1B [MSB] – Notification Type
2B – Notification Status
3B – Event/State Parameters
4B [LSB] – action:
0x00 – no action, 0xX1 – turn ON, 0xX2 – turn
OFF, 0xX3 – turn ON/OFF continuously, 0x0X
– no action on LED frame, 0x1X – LED frame
blinks red, 0x2X – LED frame blinks green,
0x4X – LED frame blinks blue, 0x8X – disable
LED frame, 0xFX – LED frame LAPD signal
(red-white-blue)
25