Advanced Parameters - FIBARO WALLI FGWDSEU-221 Operating Manual

Double switch
Hide thumbs Also See for WALLI FGWDSEU-221:
Table of Contents

Advertisement

9.2: Advanced parameters
The device allows to customize its operation to user's needs using
configurable parameters.
The settings can be adjusted via Z-Wave controller to which the de-
vice is added. The way of adjusting them might differ depending on
the controller.
In the FIBARO interface parameters are presented as simple options
in Advanced Settings of the device.
Available parameters:
1.
Description
Parameter size 1B
Default value
Available
values
2.
Description
Parameter size 4B
Default value
Available
values
Default value
Available
values
Remember device state
This parameter determines how the device will
react in the event of power supply failure (e.g.
power outage).
The parameter is not relevant for outputs set to
pulse mode (parameter 150/151 set to 2).
1 (restores the state)
0 – remains switched off after restoring power
1 – restores remembered state after restoring
power
First channel – overload safety switch
This function allows to turn off the controlled
device in case of exceeding the defined power.
Controlled device can be turned back on via
button or sending a control frame.
Single Switch Mode
0 (disabled)
0 – function disabled
10-45000 (1.0-4500.0W, step 0.1W) – power
threshold
Double Switch Mode
0 (disabled)
0 – function disabled
10-36200 (1.0-3620.0W, step 0.1W) – power
threshold
21
confIguratIon

Advertisement