11. Applicable directives and standards

Table 11-1 shows the conformant EU directives and EN standards
Directives/Standard
Directives
EMC Directives
About the laser safety
The UST laser safety standard is class 1.
Wave length・・・・・・・・・・905nm (Infrared laser)
Average laser power・・・・3.19mW or less
Beam size・・・・・80mm×5mm (distance 5000mm at the sensor's front) (For detail refer to 3.13 sections)
Standard・・・・・・・・IEC60825-1 (2007)
Accession number・・・・・1420210-000
About Laser Safety Standard Class 1: under normal operation conditions (operations which can be
foreseen rationally) it is guaranteed as safety class laser. Additional measures are not necessary to maintain
laser safety.
Table 11-1 Directives and Standards
EMC Directives
RoHS Directives
(EMI)
EN61326-1:2013
EN55011:2009 + A1:2010
(EMS)
EN61326-1:2013
EN61000-4-2:2009
EN61000-4-3:2006 + A1:2008 + A2:2010
EN61000-4-4:2012
EN61000-4-6:2009
EN61000-4-8:2010
Figure 11-1 FDA Certified labels
Do not look directly into a laser beam.
Document No: C-41-02490-9
Details
CLASS 1
LASER PRODUCT
49