HOKUYO AUTOMATIC UST-05LN User Manual page 49

Scanning laser range finder
Table of Contents

Advertisement

LED display
Synchronization
function
Surrounding intensity
Ambient temperature,
humidity
Storage temperature,
humidity
Vibration resistance
Shock resistance
Insulation resistance
*5
Log function
Protective structure
Weight
Operation life
Material
Dimensions (W×D×H)
*1
In the case installing the sensor parallel to the Emitter/Receiver surface. Minimum detectable size of the object
can be set by Area Designer.
*2
Under the factory standard testing condition using white Kent sheet.
*3
Initial setting is 66msec. ON/OFF delay function switching is possible by Area Designer. Response time can be
further delayed by a maximum of 1scan during the area switching.
*4
Initial setting is synchronization master. When using synchronization operation, refer to section 5.3 for details
about synchronization wiring. Synchronization slave setting is possible using Area Designer.
*5
The recorded distance data, level data, etc., can be confirmed using Area Designer application.
For detail refer to Area Designer UST series sensor configuration instruction manual.
48
Blue LED: ON during normal operation, blink during the start up,
configuration and malfunction state
Orange LED 1: Output 1 ON during object detection
Orange LED 2: Output 2 ON during object detection
Orange LED 3: Output 3 ON during object detection
Synchronization Master/Slave operation mode (can set by using Area
*4
Designer)
Synchronization slave mode (0°)
Synchronization slave mode (90°)
Synchronization slave mode (180°)
Synchronization slave mode (270°)
Less than 15,000 lx
Note : Avoid direct sunlight or other illumination sources as it may cause
sensor malfunction
-10°C to +50°C below 85%RH (without dew, frost)
-30°C to +70°C below 85%RH (without dew, frost)
10 to 55Hz double amplitude of 1.5mm for 2hrs in each X, Y, and Z direction
2
55 to 200Hz 98m / s
sweep of 2min for 1hr in each X,Y and Z direction
196m/s
(20G) X,Y and Z directions each 10 times
10MΩ, DC 500V Megger
No
IP65
130g (without cable )
5 years under normal temperature (motor life)
Optical window : Polycarbonate
Body : Aluminum
50×50×70(mm) (Sensor only)
Document No: C-41-02490-9