Application Examples Of The Ust; Access Protection - HOKUYO AUTOMATIC UST-05LN User Manual

Scanning laser range finder
Table of Contents

Advertisement

4. Application examples of the UST

In this chapter will explain giving some application examples that can be used.
Before installing, the user has to decide the main purpose for using the UST. Next, decide the suitable
installation place as well as required detection area size, etc. In case of area switching, it is necessary to
configure in what type of condition, how area switching will takes place.
4.1 Access protection (Horizontal application Stationary)
UST can be installed for security at an entrance or a passage way and can be used for monitoring. For
example, in order to monitor a restricted area UST is installed horizontally as one example is shown in figure
4-1. In order to monitor the entrance when the object enters, output region 1 to 3 are configured.
For example, if access penetration is detected in output region 1 and 2 then a warning is displayed, and
when access penetration is detected in output region 3 an alarm can be configured.
UST is not a safety device. It cannot be used for human protection purpose.
Before setting UST read the whole manual thoroughly.
UST
Figure 4-1 Example of access protection
UST might detect the floor. Mount it at height 200mm above the floor.
Document No: C-41-02490-9
Output region 3
Output region 2
Output region 1
27