3.14 Data logging
By connecting the UST with the Area Designer software for data logging (the log includes: distance,
intensity, output states, recording time), it is possible to record and play of log data. The operating steps are
as follows.
3.14.1 Record of log data
Follow the steps below for data recording.
① Connect UST with Area Designer.
② Click record button as shown in figure 3-13.
③ When data logging window is displayed as in figure 3-14, enter the number of scans you want to
record in the scan limit box (if the scan limit is 0, records until stop button is clicked)
④ After entering the number of scans, click start recording button as show in figure 3-14.
Select the location and enter the file name. Click save button and it starts recording.
22
Record [Ctrl +
Figure 3-13 Record buttons
Scan count indicating successful log acquisition
Scan count indicating unsuccessful log acquisition
Figure 3-14 Data logging window
In case you want to confirm the detection judgment of the area when playing
log data, it is necessary to open the original project file used while recording
the log data. Please make sure to save the project file.
Make sure that you record the data in Monitor mode. If you record in Edit
mode, output status will not be recorded in log data.
Record to "ubh" files extension. Cannot play log data in other extensions and
formats.
When "Prioritize recording (Continuous mode)" is selected in application
setting of Area Designer, then it will reduce the "Skip count". Although
"Prioritize recording (Continuous mode)" is selected, skips the log data. In
that case select "Distance only support" also. (Depending upon the
specification of computer, the data cannot be recorded in real time.)
Document No: C-41-02490-9
1]
Stop recording
Start recording