6.5 RS422 (For UST-05LA only)

Figure 6-3 shows the example of connection of RS422
UST
UST
Wire color
Pink
Yellow (Red)
Yellow (Black)
Light Blue (Red)
Light Blue(Black)
RS422 RXD-
The serial baud rates can be selected from 115.2kbps (default), 230.4kbps, 460.8kbps, and 921.6kbps and
can be set by using the Area Designer.
38
Signal
RS422 GND
RS422 TXD+
RS422 TXD-
RS422 RXD+
RS422 RXD-
Figure 6-3 Example of RS422 Connection
Document No: C-41-02490-9
1
5
6
9
D-SUB 9pin male
D-SUB 9pin
Signal
Pin No.
GND
5
RX+
3
RX-
4
TX+
2
TX-
1