AC Power

AC power is required for an unloader with an
electro-pneumatic control panel.
All electrical wiring must be done by a qualified
electrician and comply with all local codes and
regulations.
1. Route wires to control panel through electrical
conduit. Attach conduit using hole on bottom
right hand side of enclosure with a type 4X rated
conduit hub.
2. Attach the power system ground wire to the
chassis ground lug (as shown) with a minimum
14 AWG (2.0 mm
) stranded copper wire. Torque
2
to 35 in-lbs (3.95 N•m).
3A5416C
3. Connect equipment to 100 – 240 VAC, single
phase, 50/60 Hz, with a maximum 15 A branch
circuit protection and disconnect switch provided
by the installer. Use 14 AWG (2.0 mm
copper wire and attach to L1 and L2 on power
switch as shown. Torque to 8 in-lbs (0.9 N•m).

Fluid Outlet Lines

NOTICE
To prevent damage to equipment, be sure all
components are adequately sized and pressure
rated to meet the system's requirements. Refer to
the pump manual for output pressure.
1. Connect desired pump outlet fittings (not
supplied) to the fluid outlet port (1-F) of each
pump.
2. Connect a grounded, flexible fluid hose (not
supplied) to either the user-supplied fittings or
the fluid outlet port (1-F).
Installation
) stranded
2
15