LINDR PYGMY 20 Instructions For Use Manual page 14

Flow type contact cooler
Hide thumbs Also See for PYGMY 20:
Table of Contents

Advertisement

problem
beverage doesn´t flow
beverage isn't cooled enough
the beverage shoots out under
high pressure
the air compressor doesn't switch
on
air compressor doesn't switch off
excessive beer foaming
fittings do not seal properly
COOLING AND DISPENSING SYSTEMS
cause
the keg is connected wrongly
not enough air pressure (low
pressure)
the water froze after sanitation
closed compensator
setting of thermostat is not correct
bad air circulation
the machine is overheated
the pressure is too high
loose connections
the tube is not inserted correctly
damage to the tube
30
how to fix it
check it the keg coupler is connec-
ted properly
use a pump - pump air into the keg
CO2 - check the pressure in the
machine with inbuilt compensator
- turn on the switch
switch off the machine and you
have to wait until beverage will
start flowing again ( it can takes a
few minutes or up to several hours)!
move with the smal leveron the
compensator
turn the thermostat to number 7
check if the plate of the condenser
isn´t blocked
put the machine in colder surroun-
dings
lower the pressure in the keg
switch the button on the cooler,
turn the adjustment screw to the
right (K profi models)
pull out the tube, check for any
sharp edges, and if there are, cut
with knife, tighten the nuts on the
keg coupler
with Kprofi models check the
pressure on the manometer
lower the beverage temperature,
turn the thermostat to the right
compensate the beverage flow
capacity, move the little lever of
the compensator upwards
pull out the tube, check for any
sharp edges, and if there are, cut
with knife
pull out the tube and shorten 2cm