4. LUBRICATIONS
4.1 Locations
Some parts are lubricated with grease to ensure smooth operation and to
increase conductivity. If lubricated parts are replaced or grease is removed,
grease must be reapplied.
4.1.1 DOCUMENT FEED ROLLER
IF-20
Approx. 20mg
Contact between document
feed roller and grounding plate
See Fig.9 for the assembly
MOLYKOTE EM-50L
Approx. 40mg
MOLYKOTE EM-50L
Approx. 40mg
4.1.2 DRIVE GEARS
MOLYKOTE EM-50L
Approx. 20-40mg
MOLYKOTE EM-50L
Approx. 10-25mg
See Fig.12 for the assembly
MOLYKOTE EM-50L
Approx. 40-60mg
FAX-L260i 4.LUBRICATIONS
4-1