Canon FAX-L260i Service Manual page 154

Hide thumbs Also See for FAX-L260i:
Table of Contents

Advertisement

FAX-L260i Chapter 3: Maintenance & Service
#3 NUMERIC Param.
(Numeric parameter settings)
10
12
NOTE
Default
Range
01:
02:
10 (10%)
(1~99)
03:
15 (15 lines)
(2~99)
04:
12 (12 times)
(1~99)
05:
06:
07:
08:
09:
6 (6 digits)
(1~20)
10:
5500 (55 seconds)
(0~9999)
11:
3500 (35 seconds)
(0~9999)
12:
5800 (5800 lines)
(0~65535)
13:
1300 (13 seconds)
(0~9999)
14:
Item 14 to 30 :
30:
Figure 3-11 Service Data (page 3)
No. 01, 05 to 08, 12 and 14 to 30 are not used. Do not change their settings.
Regarding the T0 timer (SSSW #3 NUMERIC Param. No. 10)
When the country type (SSSW #5 TYPE) is set to "FRANCE," the default value of SSSW#3
NUMERIC Param. No.10 is "4000," but the actual T0 timer is 140 seconds. However,
when this default value is changed, the settable range of the T0 timer becomes 0-99.99
seconds. For example, if the SSSW #3 NUMERIC Param. No.10 is set to "5000," the T0
timer is 50 seconds. In addition, after changing the default value, even if the "4000" is reset,
the T0 timer will be no 140 seconds, but 40 seconds. To return the T0 timer to 140 seconds,
set the SSSW #5 TYPE to "FRANCE."
Not used
RTN signal transmission condition (1)
RTN signal transmission condition (2)
RTN signal transmission condition (3)
Not used
Not used
Not used
Not used
The number of digits in telephone number
compared against TSI signal to be matched
for restricted receiving function
Line connection detection time (T0 timer)
T1 timer (Rx)
Not used
Maximum time to receive oneline of image data
Not used
3-58