ILX Lightwave LDC-3926339 User Manual page 56

6a current source module
Table of Contents

Advertisement

Table 4.1 Command Summary
NAME
LASER:SYNCLDI?
LASER:SYNCLDV?
LASER:SYNCMDI?
LASER:SYNCMDP?
LASER:STEP
LASER:STEP?
LASER:TOL
LASER:TOL?
MODERR?
MODIDN?
MODPUD
MODPUD?
*OPC
*OPC?
*PSC
*PSC?
*PUD
*PUD?
*RCL
*RST
*SAV
*SRE
*SRE?
STATMENU:LINEn?
STATMENU:LINEn:IPD
STATMENU:LINEn:LDI
STATMENU:LINEn:PPD
STATMENU:LINEn:VF
*STB?
*TST?
*WAI
02_03
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
C O M M A N D R E F E R E N C E
PARAMETERS
FUNCTION
NONE
Synchronized measurement. Returns the laser current in
mA.
NONE
Synchronized measurement. Returns the laser voltage in
volts.
NONE
Synchronized measurement. Returns the monitor
photodiode current in µA.
NONE
Synchronized measurement. Returns the optical power.
1
Sets the current source set point step value.
NONE
Returns the current source set point step value.
2
Sets the laser set point tolerance value and time period.
NONE
Returns the laser set point tolerance value and time period.
NONE
Returns the error codes (up to 10) from the module.
NONE
Returns identification data from the module.
1
Used at factory to set product information.
NONE
Returns factory-set product information.
none
Generates the OPERATION COMPLETE message in the
Standard Event Status Register .
none
Places an ASCII character 1 into the Output Queue.
1
Used to avoid any undesirable service requests.
none
Queries the power-on-status-clear flag.
none
Stores data unique to the instrument.
none
Retrieves the contents of the *PUD storage area.
1
Recall a stored setup configuration
none
Performs a device reset.
1
Save the current setup configuration
1
Sets the Service Request Enable register bits to allow
generation of the user-selectable service requests.
none
Determines the current contents of the Service Request
Enable register.
NONE
Returns the name of the measurement that is displayed on
line n of the status menu. (n can be either 1 or 2).
NONE
Sets line n of the status menu to display photodiode
current.
NONE
Sets line n of the status menu to display laser current
NONE
Sets line n of the status menu to display optical power.
NONE
Sets line n of the status menu to display laser forward
voltage.
none
Reads the Status Byte.
Initiates an internal self-test and returns a response when
complete.
Prevents executing any further commands until the No-
Operation-Pending flag is true.
C H A P T E R
GPIB Commands
LDC-3926339
4
39

Advertisement

Table of Contents
loading

Table of Contents