ILX Lightwave LDC-3926339 User Manual page 55

6a current source module
Table of Contents

Advertisement

C O M M A N D R E F E R E N C E
4
C H A P T E R
GPIB Commands
Table 4.1 Command Summary
NAME
LASER:ENAB:COND
LASER:ENAB:COND?
LASER:ENAB:EVE
LASER:ENAB:EVE?
LASER:ENAB:OUTOFF
LASER:ENAB:OUTOFF?
LASER:EVE?
LASER:LDI
LASER:LDI?
LASER:INC
LASER:LDV?
LASER:LIM:I
LASER:LIM:I?
LASER:LIM:MDP
LASER:LIM:MDP?
LASER:LIM:V
LASER:LIM:V?
LASER:MDI
LASER:MDI?
LASER:MDP
LASER:MDP?
LASER:MODE?
LASER:MODE:IHBW
LASER:MODE:ILBW
LASER:MODE:MDI
LASER:MODE:MDP
LASER:MOD
LASER:MOD?
LASER:OUT
LASER:OUT?
LASER:SET:LDI?
LASER:SET:MDI?
LASER:SET:MDP?
38
LDC-3926339
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
PARAMETERS
FUNCTION
1
Sets the conditions that will affect the All Condition register.
NONE
Returns the value of the Condition Enable register.
1
Sets the events that will affect the All Event register.
NONE
Returns the value of the Event Enable register.
1
Sets the enable register with conditions that will turn off the
output.
NONE
Returns the value of the Outoff Enable register.
NONE
Returns the value of the Event register.
1
Sets the constant current source set point value.
NONE
Returns the constant current source measured value.
2
Increases the current source set point value by one or
more steps with user-programmable delay between steps.
NONE
Returns the measured laser voltage value.
1
Sets the laser current source limit.
NONE
Returns the laser current source limit.
1
Sets the constant optical power (from monitor PD) limit
value.
NONE
Returns the optical power (from monitor PD) limit value.
1
Sets the current source's adjustable compliance voltage.
NONE
Returns the value of the adjustable compliance voltage
setting.
1
Sets the monitor current set point.
NONE
Returns the monitor PD current measured value.
1
Sets the constant optical power set point
NONE
Returns the actual monitor PD power value
NONE
Returns the mode:
ILBW (constant current, low bandwidth),
IHBW (constant current, high bandwidth),
MDP (constant optical power) or
MDI (constant monitor current).
NONE
Sets the mode to constant current, high bandwidth.
NONE
Sets the mode to constant current low bandwidth mode.
NONE
Sets the mode to constant monitor current mode
(regardless of CALPD value).
NONE
Sets the mode to constant optical power mode.
1
Enables or disables the channel's modulation input.
NONE
Returns the status of the channel's modulation input.
1
Turns the current source output on or off.
NONE
Returns the current source output status.
NONE
Returns the constant I (current) set point.
NONE
Returns the constant optical power set point.
NONE
Returns the constant P (optical power) set point.

Advertisement

Table of Contents
loading

Table of Contents