Table 3.4 Error Message Codes

Error Code
E-103
E-104
E-105
E-106
E-114
E-123
E-126
E-201
E-202
E-203
E-204
E-205
E-206
E-207
E-208
E-209
E-210
02_03
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
Send the query ERR? to read the system errors and module error summary.
This allows you to error-check the LDC-3926 as a whole. If any module errors are
present, the corresponding bit of the module error summary is set. For example, suppose
the mainframe responds to an ERR? query with the string 0,0000000001100000. The
zero to the left of the comma indicates that there are no mainframe errors, and the binary
representation to the right of the comma indicates that there are errors on channels 7 and
6.
Send the query MODERR? to read the module errors.
For example, type CHAN 7;MODERR? to return the errors in module 7, and CHAN
6;MODERR? returns any errors in module 6. For more information about mainframe
errors, refer to the LDC-3926 Manual.
Explanation
Length of arbitrary block is different from expected length.
Parameter is an undefined numeric type.
Parameter has an invalid exponent.
A digit was expected in the parameter but was not found.
Specified arbitrary block length is invalid.
Command is not found.
Wrong number of parameters for command.
Parameter value out of range.
Error in conversion of parameter type.
Command is a "secure" command, but secure commands are disabled.
Suffix is invalid.
Expected Boolean parameter is invalid.
Error in conversion to signed 16-bit integer.
Error in conversion to unsigned 16-bit integer.
Error in conversion to signed 32-bit integer.
Error in conversion to unsigned 32-bit integer.
Error in conversion to floating-point number.