SECTION 6
A
F
E
R
IR
ILTER
LEMENT
EMOVAL
1. Clean the exterior of the air filter housing.
2. Remove the rear cap by releasing retaining
clamps.
3. Remove the element from the housing.
4. Clean the interior of the housing by using a
damp cloth. DO NOT blow out dirt with com-
pressed air as this may introduce dust down-
stream of the filter.
5. When it becomes necessary to remove the
secondary element, pull the element out of
the housing.
6. Install the new secondary element.
7. With the secondary element in place, replace
the primary element.
WARNING
DO NOT strike elements against any hard
surface to dislodge dust. This will damage
the sealing surfaces and possibly rupture
the elements.
A
F
IR
ILTER
1. Place a bright light inside the element to
inspect for damage or leak holes. Concen-
trated light will shine through the element
and disclose any holes.
2. Inspect all gaskets and gasket contact sur-
faces of the housing. Should faulty gaskets
be evident, correct the condition immedi-
ately.
3. If the clean element is to be stored for later
use, it must be stored in a clean container.
4. After the element has been installed, inspect
and tighten all air inlet connections prior to
resuming operation.
P
RIMARY
1. Place the element in position over the sec-
ondary element.
2. Install the cover with clean-out port pointing
down.
Figure 6-4: Air Filter Assembly
02250203-986 R01
E900H USER MANUAL
E
I
LEMENT
NSPECTION
A
F
E
R
IR
ILTER
LEMENT
EPLACEMENT
1. Primary Element Assembly
2. Rear Cover
3. Housing
4. Evacuator
43