Maintenance Every 250 Hours; Maintenance Every 300 Hours; Maintenance Every 1000 Hours; Maintenance Every 1500 Hours - Sullair E900H User Manual

Portable air compressor
Hide thumbs Also See for E900H:
Table of Contents

Advertisement

E900H USER MANUAL
6.7
MAINTENANCE EVERY 1000
HOURS
Perform after every 1000 hours of operation:
1. Clean the return line orifice and strainer.
2. Repack the wheel bearings on wheel-
mounted units.
6.8
MAINTENANCE EVERY 1500
HOURS
When using Sullair AWF, change the compressor
fluid and replace the fluid filter element.
Refer to "Parts Replacement And Adjustment
Procedures" on page 40 .
40
6.9
C
Warm-up the compressor for 5 to 10 minutes to
warm the fluid. Shut the compressor off and relieve
all internal pressure before proceeding. Drain the
fluid by opening the appropriate drain valve located
in the frame at the front of the machine. Close the
valve when draining is complete. Change the
compressor fluid and replace the fluid filter element.
For element replacement: See "Main Fluid Filter
Servicing" on page 41. Fill the receiver tank with fluid
according to "Lubrication Guide— Compressor" on
page 32.
R
Refer to Figure 6-1. An inspection of the running gear
should be made on a routine basis.
Figure 6-1: Running Gear Lubrication
02250203-986 R01
PARTS REPLACEMENT AND
ADJUSTMENT PROCEDURES
F
C
OMPRESSOR
LUID
HANGE
G
L
UNNING
EAR
UBRICATION
SECTION 6
P
ROCEDURE

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents