6. Re-Install the actuator tube into the incline platform mounting bracket. It may be neces-
sary to slightly rotate the actuator tube to align the clevis pin mounting holes. Choose
the adjustment direction that will minimize the change to the actuator tube reference dis-
tance. Hold the jack screw from turning while adjusting the actuator tube.
7. Return the treadmill to the upright position or remove support blocks.
8. Level the Treadmill.
9. Install the hood.
10. Connect the power cord and set the treadmill circuit breaker to ON.
11. Verify the treadmill incline operation through the full range of motion. Do the - INCLINE
TEST diagnostic test.
12. Verify treadmill operation (see ) and return to service.
.See Also
"Replacement Procedures" on page 48
"Incline Lift Motor Replacement" on page 68
Contact Precor Customer Support at support@precor.com or 800.786.8404 with
any questions.
5 Adjustment Procedures
Lift Motor Calibration
Page 44