1. Step off the running belt and operate the treadmill at 12 mph (19 kph) for one
minute.
2. Verify the running belt alignment is centered and tracking.
ESTOP Switch Test
Verify the ESTOP emergency switch operation.
1. While walking on the treadmill, press the STOP emergency button and verify that
the running belt immediately slows to a stop.
2. While walking on the treadmill, pull the ESTOP lanyard and make sure the run-
ning belt immediately slows to a stop.
3. Inspect the condition of the ESTOP lanyard clip, that the spring is in place and
that the clip will firmly hold when attached.
Heart Rate Test
Verify the Hand Held Heart Rate
LED consoles (P10, P30, P30i and P31) only
1. Access the Diagnostic menu (51765761) and run the following test:
HEART RATE TEST: Select HEART RATE TEST and follow prompts
l
run test.
Touchscreen consoles (P62, P80, and P82) only
1. Access the Service menu (51765761) and run the following test.
HEART RATE TEST: Select HEART RATE TEST and follow prompts
l
run test (System Tests (select System Settings > System Tests).
Verify the wireless heart rate monitor operation.
1. Use a wireless heart rate monitor chest strap (pn PPP000000038819103 or
2
ANT+
wireless compatible
rate icon is flashing and the HR indicator is showing the heart rate beats per
minute (bpm).
Return to service
1. Switch the power OFF.
2. Make sure that the machine is setting level and stable.
3. Make sure that any external power cords or interface cables are properly routed,
connected, and safe from being damaged.
4. On successful completion of all verification tests, return to service.
1
Hand Held Heart Rate
2
ANT+ (pronounced ant plus) is a wireless protocol for monitoring sensor data such as a per-
son's heart rate or a bicycle's tire pressure
3
Heart Rate
Contact Precor Customer Support at support@precor.com or 800.786.8404 with
any questions.
1
(HHHR
) monitor operation.
3
HR
chest strap) and verify that the console heart
3 Operation Verification