CAUTION: Do not place the Auto Stop Magnet on or near a steel structure. If the
magnet assembly comes in contact with a steel structure and then pulled away from
the steel structure, the magnet can become dislodged from the magnet assembly
housing. Contact PRECOR customer service for repair or replacement.
6. The Auto Stop system consists of a magnet holder mounted to the right front corner of
the deck and a Hall Effect sensor mounted to the drive roller bracket of the frame.
Check the alignment and gap (3/16") between the Auto Stop magnet holder and the
Auto Stop sensor. If the alignment and gap are not correct, it may be necessary to
loosen the deck and adjust so that the magnet is gaped and positioned properly relative
to the sensor. Reference Procedure, Replacing the Auto Stop Magnet. If the alignment
and the gap between the Auto Stop magnet holder and the Auto Stop sensor are cor-
rect continue with step 9.
7. The Auto Stop sensor will display a green blinking LED visible next to the connector,
indicating that power is being applied to the sensor board. The LED does not tell you if
the voltage is correct, just that it is present. If the LED is not lit or if LED is lit continue
with the next step.
Contact Precor Customer Support at support@precor.com or 800.786.8404 with
any questions.