Precor GEN06 Series Service Manual page 49

Table of Contents

Advertisement

Used belt installations:
a. If the tension is not within specification, repeat the adjustment process.
b. If the tension is within specification, continue procedure.
1
8.
Torque
the drive motor mount bolts to 204 in-lbs (17 ft-lbs, 23 N-m).
2
9.
Plug
in the power cord and switch the input power ON.
10. Run the treadmill speed at 3 mph for 1 minute.
11. Switch the power OFF and disconnect power.
12. Measure and verify that the tension measurement is within the Range Limit spe-
cification, see Drive Belt Tension Specification table. Note that there is a separate
Range Limit specification for New and Used belt installations.
a. If the belt tension is not within the Range Limit specification, repeat the tension
adjustment procedure.
b. If the belt tension is within the Range Limit specification, continue procedure.
13. Re-install hood.
14. Connect and Switch the input power ON.
15. Verify operation and return to service.
.See Also
"Adjustment Procedures" on page 39
"Drive Motor Replacement" on page 59
"Drive Belt Replacement" on page 55
1
Torque is a measure of the force that can cause an object to rotate about an axis. Bolt/nut
example: 5 nM torque is equivalent to 5 newtons of force applied one meter from the center of
the bolt, 6 ft-lb is equivalent to 6 lb of force applied 1 foot away from the center of the bolt.
2
Device power cord connector or electrical cable male connector that is inserted into an elec-
trical receptacle "outlet" (also called the plug-in).
Contact Precor Customer Support at support@precor.com or 800.786.8404 with