Led Display; Specifications - SMC Networks ITV2000 Easy Programming Manual

Microprocessor-controlled e-p regulator
Hide thumbs Also See for ITV2000:
Table of Contents

Advertisement

#
D
ERROR
ESCRIPTION
1
Input signal exceeds the input signal range
2
EPROM read/write error
3
Memory read/write error
4
Internal solenoid valve malfunction
0
Other
*Simultaneously press and hold the UP and DOWN keys for 3 seconds or longer to reset.
S
PECIFICATIONS
Supply Pressure
Output Pressure
Maximum Flow
Supply Voltage
Input Signal
Input Impedance
Linearity
Hysteresis
Repeatability
Monitor Output
Microprocessor-Controlled Electro-Pneumatic Regulator
E A S Y P R O G R A M M I N G G U I D E
[set pressure + 14.5psi] to 145psi
0.725~14.5psi (ITV201)
0.725~72.5psi (ITV203)
0.725~130.5psi (ITV205)
52.5 SCFM
24VDC±10% (ITV20 0)
12VDC±10% (ITV20 1)
4~20mADC (ITV20
0~20mADC (ITV20
0~5VDC (ITV20
0~10VDC (ITV20
250Ω or less (ITV20
approx. 6.5KΩ (ITV20
±1% FS
0.5% FS
±0.5% FS
1~5VDC analog
transistor (NPN, PNP), max. 30mA
1
Except ITV201, which is 29
ITV2000
LED
DISPLAY
E
1
R
E
2
R
E
3
R
E
3
R
E
0
R
1
-0)
-1)
-2)
-3)
-0 & -1)
-2 & -3)
.
PSI
last updated 11/03/03 10:05 AM