7.6

DRIVE-CLiQ coupling

7.6.1

Description

The DRIVE-CLiQ coupling is used to connect two DRIVE-CLiQ cables in accordance with
degree of protection IP67 acc. to EN 60529.
In addition to the data lines, the power supply contacts of DRIVE-CLiQ are also routed via
the coupling.
7.6.2

Safety information

Note
Only Siemens cables should be used for DRIVE-CLiQ connections.
7.6.3

Interface description

7.6.3.1

Overview

Figure 7-22
Booksize Power Units
Equipment Manual, (GH2), 07/2007, 6SL3097-2AC00-0BP5
DRIVE-CLiQ coupling
1
DRIVE-CLiQ coupling
2
Rating plate
3
Centering caps, Yamaichi, order no.: Y-ConAS-24-S
Accessories
7.6 DRIVE-CLiQ coupling