3.4 Basic Line Modules with internal air cooling
It is only permissible to establish connections to the DC link using the adapters that
SIEMENS has recommended (DC link adapter and DC link rectifier adapter).
The tightening torque of the DC link busbar screws (1.8 Nm, tolerance: +30 %) must be
checked before commissioning is carried out when the system is disconnected from the
power supply and the DC link is discharged. The screws must be tightened after
transportation.
CAUTION
The DC link side covers are supplied as standard with the components; they can also be
ordered separately, if required (order no.: 6SL3162-5AA00-0AA0).
Note
Only Siemens cables should be used for DRIVE-CLiQ connections.
NOTICE
If a drive line-up is switched off by means of the line disconnecting device, the voltage at
terminals 3 (EP +24 V) and 4 (EP M) must be interrupted beforehand. This can be achieved
through e.g. an auxiliary contact.