Technical Data - Siemens SINAMICS S120 Equipment Manual

Booksize power units
Hide thumbs Also See for SINAMICS S120:
Table of Contents

Advertisement

Figure 2-9
Dimension drawing: 80 kW and 120 kW Basic Line Filter
Table 2-7
Dimensions: Basic Line Filter for Active Line Modules
Basic Line
Order number
Filter
80 kW
6SL3000-0BE28-0DAx
120 kW
6SL3000-0BE31-2DAx
2.5.5

Technical data

Table 2-8
Technical data of the Basic Line Filter for Active Line Modules with Active Interface Module
Rated power
Connection voltage:
Supply voltage
Line frequency
Rated current
Power loss
1)
Weight
1 For an overview, see the power loss tables in Cabinet Design.
Booksize Power Units
Equipment Manual, (GH2), 07/2007, 6SL3097-2AC00-0BP5
2.5 Basic Line Filter for Active Line Modules with Active Interface Module
W [mm]
(inches)
479 (18.85)
6SL3000-
0BE25-5DA0
Unit
kW
55
V
380 V 3 AC -10 % (-15 % < 1 min) to 480 V 3 AC +10 %
AC
Hz
47 to 63 Hz
A
105
AC
W
41
kg
11.5
w [mm]
a [mm]
(inches)
(inches)
150 (5.90)
15 (0.59)
0BE28-0DAx
80
132
48
18.2
Line Connection Booksize
H [mm]
h [mm]
(inches)
(inches)
121.3 (4.77)
74 (2.91)
0BE31-2DAx
120
192
86
18.8
51