4.

Control unit setting

4.1 -

Dip-switch adjustment

DIP
SWITCHES
DIP
DIP-SWITCH
status
DIP 1 STEP
1-ON
2-OFF
DIP 2 AUTO
1-ON
2-ON
1-OFF
2-ON
1-OFF
2-OFF
DIP 3
ON
CHECK
OFF
DIP 4
ON
FUNCTION
OFF
DIP1 "STEP":
If the dip-switch is put to ON, the step-by-step operating mode is
activated. At every start pulse (wired or via transmitter), the control
unit performs an action. Starts the motor if the automation system is
stopped, and stops it if it is moving. If the "STEP" dip-switch is put
to OFF, the OPEN FULLY/PAUSE/CLOSE FULLY/STOP operating
mode is activated (apartment block). The control unit only accepts
commands (either wired or via transmitter) for the opening phase.
Starts again from zero with the set delay when the automation sys-
tem is open. With the automation in the opening phase, it continues
to open, and with the system in the closing phase it reopens fully.
The automation can re-close with the time set through the "PAUSE"
knob, if the "AUTO" dip-switch is set to ON. If not, it is necessary
to give a START command (either wired or via transmitter) with the
automation fully open.
12
31
Description of
operation
Step-by-step command mode:
Open / Stop / Close / Stop
Step-by-step with automatic
closing (time set with the
"Pause" knob)
Opening only command
mode with automatic closing
(condominium function)
Open / Close / Open com-
mand mode (no Stop)
Test of the safety devices
connected at terminal [3]
"Phototest" enabled
Test of the safety devices
connected at terminal [3]
"Phototest" disabled
Devices connected to "S2
Photo" terminal [4] intervene
just during closing phase with
immediate inversion
Devices connected to "S2
Photo" terminal [4] intervene
by stopping the movement
both in opening and closing
phases
DIP2 "AUTO":
If the dip-switch is put to ON, the automatic re-closing function is ac-
tivated. The control unit automatically closes the leaves after the time
set through the "PAUSE" knob (see Paragraph 4.2). If the "AUTO"
dip-switch is put to OFF, the automatic re-closing function is deac-
tivated. To close the leaves, therefore, a command must be given
(either wired or via transmitter).
DIP3 "CHECK":
If the dip-switch is put to ON, the safety devices connected to
terminal "Phototest" [3] are subject to a preventive check before
starting any movement. It's necessary to connect the positive
terminal of photocell's transmitter (or the normally closed contact of
a safety edge) to terminal n.3 in order to use this function.
If the "CHECK" dip-switch is put to OFF, the safety devices
connected to terminal "Phototest" [3] are constantly supplied.
DIP4 "FUNCTION":
If the dip-switch is put to ON, the safety devices connected to
"S2 Photo" terminal [4] intervene just during closing phase with
immediate inversion. If the dip-switch is put to OFF, the safety
devices connected to "S2 Photo" terminal [4] intervene by stopping
the movement both in opening and closing phases.
4.2 -

Knob adjustment

32
PAUSE
OBSTACLE
FORCE
KNOB
Description of
operation
FORCE
Power: adjustment of motor power. Turning the
knob clockwise increases the motor's power
and speed. To validate the modification, it is
necessary to programme the gate path.
OBSTACLE
Obstacle, sensitivity to obstacles: adjustment of
the obstacle detection function. Turning the knob
clockwise increases the drive time before obstacle
detection (less sensitivity). Therefore, in systems with
particularly unfavorable mechani- cal conditions, it is
advisable to keep the drive time high. OBSTACLE is
set at half position (50%) as factory setup.
PAUSE
Pause time before automatic gate closing.
Turning the knob clockwise increases the pause
time from 0 to 180 seconds. Please note: this
knob is functional only when AUTO dip-switch is
put to ON.
Varying the "POWER" knob has no effect until the stroke