PUSH BUTTONS

Quickly press twice
Press for 2 seconds
Press for 3 seconds
Press for 5 seconds
ADJUSTMENTS & SETTINGS
1
VISIBLE SPOTS
Quickly press the push button twice to activate the visible spots, they will help you position the curtain.
front view
Do not look directly into the visible beams !
CURTAIN POSITION
2
Quickly press twice within 1 second to show the visible spots, and then adjust the tilt angle (range: 0 to +5°) with the
screwdriver until the visible spots are at the correct position.
Recommended position for the visible spots:
If 2 m mounting height: d≥4cm
If 4 m mounting height: d≥6cm
to activate or deactivate the visible laser spots
to launch a teach-in process
to confirm the setting after changing the DIP switch
to acknowledge the 6x flashing error message and confirm that you
want the sensor to be mounted higher than 4m. Note that the sensor
does not comply with DIN 18650 and EN 16005 above this height.
If 3 m mounting height: d≥5cm
If 5 m mounting height: d≥7cm
top view