Record Settings; Sampling Frequency; Ac1 - Ac4, Dc1 - Dc4, Trigger Channel; Time - Adash VA5 Pro User Manual

Virtual unit
Table of Contents

Advertisement

ADASH

Record Settings

The Records Settings dialog opens automatically when you open a record without data. You can also open the
dialog by pressing the Recorder button when any record is opened. You don't lose any measured data by
editing the settings.

Sampling Frequency

The sampling frequency used by recording. The available frequency range of the recorded signal is in the note
under the value.
AC1 – AC4, DC1 – DC4, Trigger Channel
Switch to on all channels you want to record.

Time

Define the length of record.

Start of Rec

freerun
The recording is started immediately after the measurement's preparation.
external
The external signal (voltage level higher then defined threshold level in the Trigger Settings) starts the
recording. Such signal may be generated for example when the machine starts to work. This type of signal is
usually created in the control system.
amplitude
The recording is started when the signal level exceed the Ampl Trig Level on Ampl Trig Channel. The Ampl
Trig parameters are available only if the amplitude is chosen.