ADASH
ISO 10816 Machine Groups
You can set the appropriate machine group according the ISO 10816 for each channel separately or for all
channels together.
ISO 10816 Classification of machinery. These parameters are used for limit values according to machine type,
nominal power or shaft height.
Bearing Settings
The fault bearing frequencies can be displayed in spectra. The bearing type definition is required for that.
Bearing type
Select Bearing Type item and press OK button or right arrow button. From next list select required item and
press OK button. Also recently used bearings are displayed.
database
selection from database
Enter the name (or part of the name) and use the up/down arrows. Confirm by OK.
user
If the required bearing is not contained in the database, then you can define the parameters manually.
undef
none bearing defined, the fault frequencies will not be displayed
Rotating Race
The selection of rotating race is required for correct calculation of fault frequencies.
DC Sensors
DC sensors are used for discrete current signals, for example temperature, pressure, ... .
After selection of DC1 - DC4 or All DC Channels item the sensor properties menu appears.
Sensitivity [mV/unit]
Sensitivity value
Offset [mV]
Offset value
The used formula: output value in Unit = (input value in mV - Offset) / Sensitivity.
Unit
Unit selected from the list or user unit
For further technical and contact information visit
38
www.adash.com
or email: info@adash.com
Adash 4500 – VA5Pro