Usually the taking of measurement (for example time signal) begins exactly from the trigger moment. But in
some applications you are interested also to know the signal before trigger. The required time should be define
in seconds, but in signal Analyzers is usually defined as percent part of the total signal length. When 1 second
time signal is measured and pretrigger=25, then 0,25s will be taken before trigger and 0,75s after trigger. Also
the negative pretrigger could be used. It means that the time signal will be taken later then trigger pulse.

Runup

The Runup menu contains parameters for Runup module.
Max Memory Size [MB]
It enables partial savings of runup measurement. If the size of measured data exceeds the value, then data are
saved and new runup is opened.
Time Unit
days, hours, minutes
The unit of Length parameter (see next line)
Length
undef, value
If defined, then measured data are saved to individual files, where each file contains defined length.
Trend Time Axe
relative
the time axe begins from zero
real time
the time of measurement is displayed on time axe
Trend Length
auto, value
The length of the trend graph (the range of X axe). It is used for Runup measurement and for the Graph
Properties / View Trend. When the auto is used, then all data in the trend are displayed.
Spectrum Settings
Some spectrum Graph Properties parameters can be predefined here. Every new created spectrum graph has
these parameters set to values form this menu. More detailed description of each parameter will be stated in
chapter about Graph Properties for spectrum.
Detect Type
RMS, 0-P, P-P