Q40 Tape Library
Event Code
Message Text and Description
Library test failed due to spooling
2010
mechanism defect.
Drive Power Board has failed.
2011
2012
Multiple bottom covers detected.
2013
Multiple top covers detected.
Bottom cover is missing.
2014
2015
Top cover is missing.
Module alignment mechanism is not
2016
locked properly.
2017
A communication problem between
modules was detected.
Too many unit position
2018
transmitter/detector failures.
Database access error.
2021
Drive has been hot removed while in
2022
active status as LUN master.
Internal software error.
2023
2024
Exception thrown by application not
handled.
2027
Move failed pulling cartridge from slot.
511026 Rev. 07-01-19
Installation and Operations Manual
Details and Solution
Ensure that the spooling mechanism is fully seated
in the base module and connected correctly to the
robotic assembly.
Ensure the drive power board is fully seated in the
module and power cycle the library.
Remove all bottom covers except from the bottom
module in the library.
Remove all top covers except for the top module in
the library.
Install the bottom cover on the bottom module of the
library, also check the module interconnect cable
and module power cords. If the base module
cannot detect both a top and bottom cover the robot
will not move.
Install the top cover on the top module of the library.
Check the module interconnect cable and module
power cords. If the base module cannot detect both
a top and bottom cover the robot will not move.
Ensure that the alignment mechanism is engaged in
every module that is above another module in the
library.
Ensure that all modules are powered and have the
interconnect cable properly attached. Also, ensure
that the module alignment locks are in the correct
positions.
Ensure that the alignment mechanism is engaged in
every module that is above another module in the
library. Perform a power cycle.
Restore a configuration backup and perform a
power cycle.
Reinstall the removed drive at the same position as
it was removed.
Contact Technical Support for firmware upgrade.
Contact Technical Support for firmware upgrade.
Check for labels or cartridge misalignments.
Verify there are no obstructions at the bottom of the
library.
Power cycle the library and verify no further critical
events were generated.
154