Sample Application - Siemens TC65 Hardware Interface Description

Hide thumbs Also See for TC65:
Table of Contents

Advertisement

TC65 Hardware Interface Description
Strictly confidential / Draft
7

Sample Application

Figure 38 shows a typical example of how to integrate a TC65 module with a Java
application. Usage of the various host interfaces depends on the desired features of the
application.
Audio interface 1 demonstrates the balanced connection of microphone and earpiece. This
solution is particularly well suited for internal transducers. Audio interface 2 uses an
unbalanced microphone and earpiece connection typically found in headset applications.
The charging circuit is optimized for the charging stages (trickle charging and software
controlled charging) as well as the battery and charger specifications described in Section
3.5.
The PWR_IND line is an open collector that needs an external pull-up resistor which
connects to the voltage supply VCC µC of the microcontroller. Low state of the open collector
pulls the PWR_IND signal low and indicates that the TC65 module is active, high level
notifies the Power-down mode.
If the module is in Power-down mode avoid current flowing from any other source into the
module circuit, for example reverse current from high state external control lines. Therefore,
the controlling application must be designed to prevent reverse flow.
If the I
2
C bus is active the two lines I2CCLK and I2DAT are locked for use as SPI lines. Vice
versa, the activation of the SPI locks both lines for I
by using the AT^SSPI command.
The internal pull-up resistors (Rp) of the I
supply or to the VEXT line of TC65. The advantage of using VEXT is that when the module
enters the Power-down mode, the I
the resistors to an external power supply, take care that the interface is shut down when the
PWR_IND signal goes high in Power-down mode.
The USB interface and the second serial interface ASC1 have different functions depending
on whether Java is running. Under Java, ASC1 is defined as System.out which only needs
the RXD1 line of TC65. If Java is not used all the 4 lines of ASC1 are available as serial
interface lines (TXD1, RXD!, RTS1, CTS1). The USB interface can be used as debug
interface for the Java environment, without Java it is a full-featured USB port.
The EMC measures are best practice recommendations. In fact, an adequate EMC strategy
for an individual application is very much determined by the overall layout and, especially,
the position of components. For example, mounting the internal acoustic transducers directly
on the PCB eliminates the need to use the ferrite beads shown in the sample schematic.
However, when connecting cables to the module's interfaces it is strongly recommended to
add appropriate ferrite beads for reducing RF radiation.
Disclaimer
No warranty, either stated or implied, is provided on the sample schematic diagram shown in
Figure 38 and the information detailed in this section. As functionality and compliance with
national regulations depend to a great amount on the used electronic components and the
individual application layout manufacturers are required to ensure adequate design and
operating safeguards for their products using TC65 modules.
TC65_HD_V00.521
2
C. Settings for either interface are made
2
C interface can be connected to an external power
2
CI interface is shut down as well. If you prefer to connect