Delta HES Series User Manual page 76

Hybrid energy system
Hide thumbs Also See for HES Series:
Table of Contents

Advertisement

Multi-function output direction
Control mode
VF
FOCPG
Settings
This parameter is used for bit-wise setting. If the corresponding bit is 1, the multi-function
output is set as reverse direction.
Low-pass filtering time of keypad display
VF
FOCPG
Control mode
Settings
This parameter can be set to reduce the fluctuation of the readings on the keyapd.
Maximum output voltage for pressure feedback
Control mode
VF
FOCPG
Settings
Minimum output voltage for pressure feedback
Control mode
VF
FOCPG
Settings
This parameter defines the pressure feedback output voltage type.
If the pressure feedback has a bias, can adjust this parameter to eliminate the bias.
Type of Pressure Feedback Selection
VF
FOCPG
Control mode
Settings
PO (Pressure Feedback) terminal: Add a current-fed pressure feedback (4~20mA)
The following are required when using it:
Switch the SW100 on the I/O board to "I".
Set Pr03-12 = 0 (4~20mA)
Set Pr00-36 =1 (Enable detection of the pressure feedback disconnection)
Confluence Master/Slave Selection
VF
FOCPG
Control mode
Settings
In a stand-alone system, this parameter is set as 0
In a confluence system, the parameter is set as 1 for the Master and 2 for the Slave
With multi-function input terminal function 45, the confluence/diversion can be configured. For
detailed operation, please refer to Chapter 2 for wiring and Chapter 3 for tuning.
The difference between Master 2 and Master 3 is that the Master 3 can be configured as
confluent with other Slaves during confluence, however, the Master 2 can be configured for
stand-alone operation.
When Pr.03-13 is set as 2: Slave, at the same time, Pr.01-01 will be set as 2 and Pr.03-15 will
be set as 1 automatically.
FOCPM
0~65535
FOCPM
0.001~65.535 seconds
FOCPM
5.0~10.0 V
FOCPM
0.0~2.0V
FOCPM
0:
Current
1:
Voltage
FOCPM
0: No function
1: Master 1
2: Slave/Master 2
3: Slave/Master 3
4-33
Chapter 4 Parameter Functions
Factory default: 0
Factory default: 0.010
Factory default: 10.0
Factory default: 0.0
Factory default: 1
Factory default: 0
|HES Series