Delta HES Series User Manual page 47

Hybrid energy system
Hide thumbs Also See for HES Series:
Table of Contents

Advertisement

Chapter 4 Parameter Functions
Parameter
Function of the parameter
code
Ramp down rate of flow
00-32
command
00-33
Valve opening delay time
00-34
Reserved
Over-pressure detection
00-35
level
Detection of disconnection
00-36
of pressure feedback
00-37
Differential gain
Pressure/flow control
00-38
function selection
00-39
I gain of pressure overshoot
1
00-40
Reserved
00-41
Reserved
00-42
Pressure overshoot level
00-43
Percentage of maximum
flow
00-44
Pressure command
00-45
Percentage of flow
command
00-46
Pressure reference S1 time 0~1000ms
00-47
Pressure reference S2 time 0~1000ms
00-48
Flow reference S1 time
00-49
Flow reference S2 time
|HES Series
0~1000 ms
0~200 ms
0~400Bar
0 : No function
1: Enable (only for the pressure feedback output signal
within 1~5V)
0.0~100.0 %
Bit 0: 0: Switch the PI Gain according to the pressure
feedback level
1: Switch the PI Gain according to the
multi-function input terminal
Bit 1: 0: No pressure/flow control switch
1: Switch between the pressure and flow control
0.00~500.00 seconds
0~100%
0~100%
0~400 bar
0~100%
0~1000ms
0~1000ms
Settings
4-4
Default
value
80
0
230
0
0.0
0
0.2
2
100
0
0
0
0
0
0