Delta HES Series User Manual page 28

Hybrid energy system
Hide thumbs Also See for HES Series:
Table of Contents

Advertisement

Terminal
Function
SON
Run-Stop
EMG
Abnormal input from outside
RES
Reset
MI3
Multiple Function Input: Option 3
MI4
Multiple Function Input: Option 4
MI5
Multiple Function Input: Option 5
Common terminal of digital control
COM
signals (Sink)
Common terminal of digital control
+E24V
signals (Source)
Common terminal of digital control
DCM
signals (Sink)
Malfunctioning abnormal connection
RA
1 (Relay always open a)
Malfunctioning abnormal connection
RB
1 (Relay always closed b)
RC
Multi-function Relay Common
Multi-function Output 1
MO1
(Photocoupler)
Multi-function Output 2
MO2
(Photocoupler)
Multi-function Output Common
MCM
(Photocoupler)
PO
PO/PI/QI circuit
PO/PI/QI
PI
ACM
QI
+10V Configuration Voltage
Power supply terminal of pressure
+24V
sensor
Between terminals SON-DCM: conducting (ON) ; run: open
circuit (OFF), Stop
Abnormal input from outside
reset
No function is set for default setting
When conducting (ON), input voltage is 24Vdc (Max:30Vdc)
and output impedance is 3.75kΩ ; In open circuit (OFF), the
allowable leakage current is 10μA
Common terminal of multiple function input terminals
+24V 80mA
Common terminal of multiple function input terminals
Resistive Load:
5A(N.O.)/3A(N.C.) 240VAC
5A(N.O.)/3A(N.C.) 24VDC
Inductive Load:
1.5A(N.O.)/0.5A(N.C.) 240VAC
1.5A(N.O.)/0.5A(N.C.) 24VDC
Hybrid Servo Controller outputs various types of monitoring
signals with the transistor operating in open collector mode.
Max. 48VDC 50mA
Pressure Feedback
Impedance:200kΩ
Resolution:12 bits
Range:0 ~ 10V or 4~20mA=
PO/PI/QI Circuit
To input current, firmware v2.04 or above and a new I/O
control board (the one has SW100 switch) are required.
See parameter 03-12 for more information.
Pressure Command
Impedance:200kΩ
Resolution:12 bits
Range:0 ~ 10V=
Internal Circuit
Flow Rate Command
Impedance:200kΩ
Resolution:12 bits
Range:0 ~ 10V=0~maxium flow rate
Power supply for analog configuration +10Vdc 20mA
(variable resistor 3~5kΩ)
Configuration power supply for pressure sensor +24Vdc
100mA
Factory Setting (NPN mode)
MO1
MO2
Internal circuit MCM
0~maximum Pressure Feedback value (Pr.00-08)
0~maximum pressure command value (Pr.00-07)
2-15
Chapter 2 Wiring|HES Series
Max: 48Vdc/50mA
~

Hide quick links:

Advertisement

Table of Contents
loading