Procedure
1. Open the left and right front covers.
Important:
Be sure to open both the right and left front covers. You could damage the right
cover if you remove the fusing unit with the right cover closed.
2
2. Remove the handle for replacing the fusing unit; this is stowed in a recess at
the bottom left of the machine.
3. Turn lever C2 to the left, and then carefully pull out the fusing unit drawer until it
stops.
1
2
1
bzs124
bzs151
bzs101
55