OVMS: Renault Twizy User Guide
Command
CFG RAMPS [start‰]
[accel%] [decel%]
[neutral%] [brake%]
CFG RAMPS
CFG RAMPL [accel%]
[decel%]
CFG RAMPL
CFG SMOOTH [level%]
CFG SMOOTH
CFG BRAKELIGHT [on_lev]
[off_lev]
Function
Set rates of torque demand changes (higher means faster).
start‰: 1..250, default 40 (T45: 30)
accel%: 1..100, default 25 (T45: 21)
decel%: 0..100, default 20
neutral%: 0..100, default 40
brake%: 0..100, default 40
Omitted parameters will use their default values.
New for version 3.4.0: the interpretation of the "start" parameter
changed from percent to per mille, you need to adjust your
configurations!
Reset ramp rate configurations to default.
Set rpm change limits for ramps.
accel%: 1..100, default 30 = 6000 rpm/s
decel%: 0..100, default 30 = 6000 rpm/s
Omitted parameters will use their default values.
Reset ramp change limits to default.
Set smoothing curve (S-curve) level.
level%: 0..100, default 70
Reset smoothing configuration to default.
V3.6: command has been excluded from default firmware build
due to ROM space issues.
Set brake light controls for neutral braking.
levels: 0..100 default 100 = control disabled
These are deceleration levels with 100 = ~14 m/s².
Submitting only one parameter will set both to the same value.
NOTE: sadly, this will not work without a hardware modification,
as the Twizy brake light does not seem to be controllable by the
SEVCON. If you know how to do this modification, please share
your knowledge. Additional info: brake light signal should be
available at pins 11+12 of the SEVCON connector.
NOTE: this command will need to go pre-operational, so the
vehicle needs to be stopped.
52 / 77
2019/05/02 RT3.9.1
Need help?
Do you have a question about the OVMS and is the answer not in the manual?
Questions and answers