OVMS User Manual page 48

Renault twizy open vehicle monitoring system
Table of Contents

Advertisement

OVMS: Renault Twizy User Guide
Command
CFG POWER [torque%]
[power_low%] [power_high
%] [current%]
CFG POWER
Function
Set maximum motor torque for starting, maximum motor power
output levels (mechanical) for low and high speed and (V3.7)
optionally maximum current level.
Without current%:
torque%: 10..130 (128), default 100
power_low%: 10..139, default 100
power_high%: 10..130, default 100
With current% (V3.7):
torque%: 10..254, default 100
power_low%: 10..254, default 100
power_high%: 10..254, default 100
(V3.7) current%: 10..123, default none
100% torque = 55 Nm = default
128% torque = 70.125 Nm = max
104% torque = ~57 Nm = motor peak rating
100% power_low = 12182 W = default turning point
100% power_high = 13000 W = motor peak rating
Submitting only one parameter will set the first three levels to the
same value, disable current control and use upper safety limits. If
submitting two parameters, the first will be used for the torque
level, and the second one will be used for both power levels.
(V3.7) Setting current% to any valid value (even 100) will enable
current control and disable upper safety limits for torque% and
power...%.
ATT: Raising can overload the motor and controller!
Monitor temperature levels!
NOTE: this command will need to go pre-operational, so the
vehicle needs to be stopped. Also a power cycle should be done
after using this command.
Reset motor torque and power configuration to default.
NOTE: this command will need to go pre-operational, so the
vehicle needs to be stopped. Also a power cycle should be done
after using this command.
48 / 77
2019/05/02 RT3.9.1

Hide quick links: