Command
BATT
-or-
BATT S
BATT V
BATT VD
BATT T
BATT TD
Function
Output current alert and watch status. This will be sent
automatically if any alert condition changes, but not on watch
conditions.
Example:
Volts: SD:5mV ?C1:+10mV Temps: SD:1C OK
Read: Max standard deviation has been 5mV / 1°C. Cell 1 had a
max deviation of 10 mV above average, thus has been tagged
"suspicious". An alert would be tagged by a "!". Temperatures
have been nominal.
Output current voltage levels.
Example:
P:57.50V ?1:4.120V 2:4.110V 3:4.110V 4:4.110V
5:4.110V 6:4.110V 7:4.110V 8:4.110V 9:4.110V
10:4.110V 11:4.110V 12:4.105V 13:4.105V 14:4.120V
Read: Pack voltage is 57.5 V, followed by the 14 cell voltages.
Note the "?" tagging the suspicious cell. Precision of cell
voltages is 0.005 V.
Output collected max voltage deviations.
Example:
SD:5mV ?1:+10mV 2:+0mV 3:+0mV 4:+0mV 5:+5mV 6:+0mV
7:+0mV 8:+0mV 9:+0mV 10:+0mV 11:+0mV 12:-5mV 13:-
5mV 14:+10mV
Read: Standard deviation was at most 5 mV. Cell 1 (suspicious)
was at most 10 mV above average, cell 12+13 had a max
deviation of 5 mV below average. Note cell 14 also once had
+10 mV deviation, but that did not trigger the "watch" flag, so
was inside standard deviation at that time.
Output current cell module temperatures.
Example:
P:10C (8C..10C) 1:10C 2:10C 3:10C 4:10C 5:10C 6:10C
7:10C
Read: Current pack temperature is 10 °C, module temperature
range of last usage was from 8..10 °C. Following are the 7
module temperatures, no watches or alerts.
Output collected max temperature deviations.
22 / 77