No.
Items
Optional Function
Remote Control Run/Stop
77
J4
Prohibit by Central Controller (*9)
78
J5
Not Prepared
79
J6
Not Prepared
80
J7
Not Prepared
81
J8
Eco-operation (*10)
82
J9
Not Prepared
83
JA
Not Prepared
84
Jb
Not Prepared
Calibration for Thermistor of Wired
85
JC
Controller
86
K1
Not Prepared
87
K2
Not Prepared
88
K3
Not Prepared
89
K4
Not Prepared
90
K5
Motion Sensor Detection Level
Operation Setting during
91
K6
Thermistor of Wired Controller
or Remote Sensor
Radiation Temperature Sensor
92
K7
Calibration
Control of Dew Condensation
93
K8
Prevention
(Only for Mini Cassette Type)
94
K9
Not Prepared
95
KA
Not Prepared
96
L1
Setting Position of Motion Sensor
97
L2
Not Prepared
Louver Setting during Energy-Saving
98
L3
Forced Thermo-OFF
(Only for Mini Cassette Type)
Fan Speed during Energy-Saving
99
L4
Forced Thermo-OFF
Louver Swing Operation
100
L5
Energy-Saving Forced Thermo-OFF
12
Individual
Setting
Setting
Condition
00
No Setting (Factory Default)
×
01
RC Run/Stop Operation Prohibited
02
RC Run Operation Prohibited
-
-
Not Used (Use as 00 setting conditions)
-
-
Not Used (Use as 00 setting conditions)
-
-
Not Used (Use as 00 setting conditions)
00
Not Available
×
01
Available
-
-
Not Used (Use as 00 setting conditions)
-
-
Not Used (Use as 00 setting conditions)
-
-
Not Used (Use as 00 setting conditions)
00
0°F ( 0°C)
01
–1°F (–0.5°C)
02
–2°F (–1.0°C)
03
–3°F (–1.5°C)
04
–3°F (–2.0°C)
05
–4°F (–2.5°C)
06
–5°F (–3.0°C)
07
–6°F (–3.5°C)
×
08
+1°F (+0.5°C)
09
+2°F (+1.0°C)
10
+3°F (+1.5°C)
11
+3°F (+2.0°C)
12
+4°F (+2.5°C)
13
+5°F (+3.0°C)
14
+6°F (+3.5°C)
15
0°F ( 0°C)
-
-
Not Used (Use as 00 setting conditions)
-
-
Not Used (Use as 00 setting conditions)
-
-
Not Used (Use as 00 setting conditions)
-
-
Not Used (Use as 00 setting conditions)
00
Standard
○
01
High
02
Low
00
ALL
01
COOL/DRY
○
02
HEAT
03
ALL
00
Normal
01
Upper
○
02
Lower
03
Normal
00
Not Available
○
01
Available
-
-
Not Used (Use as 00 setting conditions)
-
-
Not Used (Use as 00 setting conditions)
00
A
01
B
○
02
-
03
D
-
-
Not Used (Use as 00 setting conditions)
00
Recive Air: Low (Standard)
01
Recive Air: Medium
○
02
Recive Air: High
03
Not Available
00
Not Available (Standard)
○
01
Available
00
Not Available
○
01
Available