Page 1
FAULT CODE TROUBLESHOOTING INDEX 1. Red Flashing LED Light and Audible Alarms indicate there is a Leak Detected for the Counter Top Model 2. Green Flashing LED light indicates the PCB CDS DIP switch turned to OFF FAULT CODE: Red Flashing LED Light and Audible Alarms are the Leak Detector Alarms for Counter Top Model Possible Reason Solution Water exiting drip tray due to Empty Drip Tray. Remove Top cover and Front Panel prior to being full drying out inside of the unit. Water is in the bottom of the unit. Open up unit to determine where the leak is. Leak in WL250 Counter Top Check for source of leak. Dry out inside of unit. Flashing Red Light WL250 Manual Page 51 ‐ Revision: 12‐12‐2018 ...
Page 2
FAULT CODE: Green Flashing LED light indicates the PCB CDS DIP switch turned to OFF Flashing Green Light Possible Reason Solution Change CDS DIP Switch’s on the PCB for Leak Detection Part CDS Sensor switched to OFF Number 12‐3115 (Factory PN EN‐6085A) to ON. Both switches to be in ON position as shown WL250 Manual Page 52 ‐ Revision: 12‐12‐2018 ...
Need help?
Do you have a question about the WL250 and is the answer not in the manual?
Questions and answers