HOT WATER TROUBLESHOOTING INDEX 
Hot Water Problems
1. Hot Water is not Hot 83°C (181° +/- 5°F)
Also includes related instructions for Resetting the Hot Tank Overload or High Limit
Safety
 
1. Hot Water is not Hot 83°C (181° +/‐ 5°F) 
 
NOTE:  The WL270 Water Treatment System does NOT have Sleep or Power Saving Mode and the 
hot water should be a minimum of 181°F under normal operating conditions. 
 
The Hot temperature set point is 181° F and is controlled by a thermostat on the side of the tank. 
 
There is a resettable overload or high limit safety above the thermostat on the side of the tank that 
will trip to prevent damage to the unit if the tank is dry heated (turned on without water in it). 
 
The WL270 Water Treatment System does NOT have Extra Hot capability and the maximum hot 
temperature is 186°F. 
 
It typically takes 10 minutes for the 600W Hot Tank to heat the 1.6 Liter of room temperature 
(ambient) water to the 83°C (181°F) set point.
 
Possible Reason 
No power to heater elements 
Hot Tank Overload Devices 
(High Safety Limit) tripped   
 
Hot Tank Overload Devices 
(High Safety Limit) is a safety 
feature to ensure the tank 
does not overheat. 
Hot Tank Overload Devices 
(High Safety Limit) "open" on 
Hot Tank 
WL270 Manual 
 
 
Check that the Red Heater and Compressor 
switch is on. 
 
Turn Red Heater and Compressor Switch on.   
I = ON 
Hot Tank Overload Devices (High Safety Limit) will "click" 
when pushed.  The Hot Tank Overload Devices (High Safety 
Limit) are automatically reset when pressed.   
 
See Resetting Hot Tank Overload Devices (High Safety Limit) 
Instructions that are included further below in this 
Troubleshooting Section 
Turn Power off.   
 
Check OHM's resistance across terminals on each of the Hot 
Tank Overload Devices (High Safety Limit) separately. Good 
components will indicate a closed circuit or zero OHM's on 
the meter. 
Replace components as necessary. 
                                                                    Page 51 – Revision 3‐4‐2019 
Solution 

Advertisement

loading
Need help?

Need help?

Do you have a question about the WL270 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for WaterLogic WL270

  • Page 1   Hot Water Problems 1. Hot Water is not Hot 83°C (181° +/- 5°F) Also includes related instructions for Resetting the Hot Tank Overload or High Limit Safety   1. Hot Water is not Hot 83°C (181° +/‐ 5°F)    NOTE:  The WL270 Water Treatment System does NOT have Sleep or Power Saving Mode and the  hot water should be a minimum of 181°F under normal operating conditions.    The Hot temperature set point is 181° F and is controlled by a thermostat on the side of the tank.    There is a resettable overload or high limit safety above the thermostat on the side of the tank that  will trip to prevent damage to the unit if the tank is dry heated (turned on without water in it).   ...
  • Page 2 Turn Power off.  Check OHM’s resistance across terminals on  each Thermostat and Overload separately.    Thermostat or overload  Good components will indicate a closed circuit or zero  “open” on Hot Tank  OHM’s on the meter.    Replace components as necessary.  Visually inspect wire leads gong to the hot tank; confirm  proper connections to the heating elements.  Loose or improperly    connected wire(s) to the   Hot tank life is 3‐5 years, depending on usage.    heating element / hot tank.    *Typically, dealers swap out the hot tank at site, take back to  the shop to repair.  Turn Power off; Drain hot tank; Use multi‐meter to check  heater element for approximately 26 OHM’s resistance.    Heating Coil not Working  Hot tank must be empty if you are checking for continuity.      Replace Hot Tank as necessary.          WL270 Manual                                                                      Page 52 – Revision 3‐4‐2019 ...
  • Page 3 RESETTING THE HOT TANK OVERLOAD OR HIGH LIMIT SAFETY               1.  Turn off Red Heater and Compressor Power Switch O = OFF on rear of unit.   2.  Unplug the Power Cord from rear of unit.         Remove 4 Phillip Screws from the Access Panel on rear  3.  of unit and Lower Access Panel.    Locate protective metal box on rear of Hot Tank.  Push down on top of metal box to  access thermostat and overload      4.    Press the reset button 5.    Reattach the metal box by depressing the top flap of the metal box so it snaps back into  6.  its original position on the Hot Tank.  WL270 Manual                                                                      Page 53 – Revision 3‐4‐2019 ...
  • Page 4         7.  Replace the Access Panel and 4 Philips screws.   8.  Plug in the Power Cord.    Make sure the hot and cold tanks are filled with water BEFORE turning on the Red  Heater and Compressor Power Switch  9.            CAUTION!  NEVER TURN ON HEATER BEFORE FILLING HOT TANK.  Red Heater and Compressor Power Switch must be in the O=OFF position    while the Hot Tank is empty.  Damage could occur within one minute and    the overload (high limit) will require manual reset if heater is turned on  with an empty Hot Tank.  10.  Verify the cooler is fully operational before installing it at the customers’ site.        WL270 Manual                                                                      Page 54 – Revision 3‐4‐2019 ...