1. Red Heater and Compressor Power Switch won't light, and the Red LED on 
the Front won't light 
 
2. Red Power Switch is lit but the red LED on the Front is not lit 
 
3. Compressor Runs but does Not Chill 
 
4. Compressor is Not Running  
 
 
1. Red Heater and Compressor Power Switch won't light and the Red LED on 
the Front won't light 
 
 
Possible Reason 
Circuit Breaker 
Fuse is Blown 
Defective / Loose Power Cord 
Failed Power Line Noise Filter, 
ElectroMagnetic Interference 
filter (EMI) 
Defective Red Heater / 
Compressor Switch 
 
 
 
 
 
WL250 Manual 
POWER TROUBLESHOOTING INDEX 
Check the Circuit Breaker 
Replace Fuse 
Check that power cord is properly plugged in.  If it is properly 
plugged in, use a different power cord to verify. 
Replace Power Line Noise Filter, ElectroMagnetic Interference 
filter (EMI) 
Replace Red Heater / Compressor Switch 
                                                      Page 53 ‐ Revision: 12‐12‐2018 
 
Solution 

Advertisement

loading
Need help?

Need help?

Do you have a question about the WL250 and is the answer not in the manual?

Questions and answers

Summary of Contents for WaterLogic WL250

  • Page 1   2. Red Power Switch is lit but the red LED on the Front is not lit    3. Compressor Runs but does Not Chill    4. Compressor is Not Running       1. Red Heater and Compressor Power Switch won’t light and the Red LED on  the Front won’t light      Possible Reason  Solution  Circuit Breaker  Check the Circuit Breaker  Fuse is Blown  Replace Fuse  Check that power cord is properly plugged in.  If it is properly  Defective / Loose Power Cord  plugged in, use a different power cord to verify.  Failed Power Line Noise Filter,  Replace Power Line Noise Filter, ElectroMagnetic Interference  ElectroMagnetic Interference  filter (EMI)  filter (EMI)  Defective Red Heater /  Replace Red Heater / Compressor Switch  Compressor Switch            WL250 Manual                                                        Page 53 ‐ Revision: 12‐12‐2018 ...
  • Page 2 3. Compressor Runs but Does Not Chill  Possible Reason  Solution  Condenser is dirty  Clean the condensing coil of any obstructions or dust.  Make sure unit is not under minimum ventilation requirements (2  Reduction of airflow into unit.  to 4 inches).  Compressor is running very  Low or lost refrigerant.  Refrigerant recharge required.  hot.    4. Compressor is Not Running  Possible Reason  Solution      Red Heater and Compressor  Turn Red Heater and Compressor Switch on.    Switch button on unit is in the  I = ON  off position    Turn Red Heater and Compressor Switch off.  O = OFF.    Remove the compressor cap on side of the compressor;      Disconnect the black and red terminal connectors;     Compressor Starting Circuit  Inspect the starter and overload relay for any defects.      Replace components(s) as needed.    Turn Red Heater and Compressor Switch on I = ON and retest  compressor operation.  WL250 Manual                                                        Page 54 ‐ Revision: 12‐12‐2018 ...