4.2 Join Into Lora Network

To join R718CT2/CK2/CR2 into LoRa network to communicate with LoRa gateway.
The network operation is as following:
After the device is powered on, it starts to actively search for the network. If it searches a network
that can be joined, the green indicator light will stay on for 5 seconds to indicate that the network is
successfully joined. Otherwise, the indicator light does not work;

4.3 Function Key

(1) Press and hold the function key for 3 seconds to turn on the device, and the green LED flashes
once.
(2) Press and hold function key for 5 seconds to reset to factory setting. After restoring to
factory setting successfully, the green indicator will flashes quickly 20 times.
(3) Press function key to turn on the device which is in the network and the green indicator will flash
once and the device will send a data report.

4.4 Data Report

When the device is turned on, it will immediately send a version package and a data report of
temperature/voltage. The transmission frequency of data report is once every hour.
ReportMaxTime: 3600s;
ReportMinTime: 3600s;
ReportChange:
TempChange:
Data report configuration and sending period are as following:
Min Interval
(Unit:second)
Any
number
between 1~65535
0.1V;
1℃;
Max Interval
Reportable
(Unit:second)
Change
Any
number
Can not be 0.
between 1~65535
Current
Change≥
Reportable Change
Report
per Min Interval
4
Current
Change <
Reportable Change
Report
per Max Interval