See Through (St) Framing Diagram - ORTAL Lyric Front Facing Series Installation And Operation Manual

Built-in models:
Table of Contents

Advertisement

See Through (ST) Framing Diagram

Model
Framing
110 ST
110 ST
Dimension A – Metal: fireplace height + 1/4" (for maneuvering)
Dimension A – Wood: fireplace height + 1/4" (for maneuvering)
Dimension B – Metal: fireplace width
Dimension B – Wood: fireplace width + 5/8" + 5/8" (type X drywall on either side)
Dimension C – Metal: fireplace depth – 1/2"– 1/2" (drywall lips)
Dimension C – Wood: fireplace depth – 1/2"– 1/2" (drywall lips)
Dimension D – Metal: pipe diameter + 1" right side clearance + 1" left side clearance
Dimension D – Wood: pipe diameter + 1" right side clearance + 1" left side clearance
*If you plan on putting a TV or artwork over the fireplace, use Wood framing values.
20
Dimension A
Metal*
42-1/16"
Wood
42-1/16"
Dimension B
Dimension C
51-9/16"
15-3/4"
52-13/16"
15-3/4"
Lyric Installation Manual: Built-in Models, April 2019
Dimension D
10"
10"