Securing The Fireplace; Access Panel - ORTAL Lyric Front Facing Series Installation And Operation Manual

Built-in models:
Table of Contents

Advertisement

To raise the fireplace, build a platform to which the fireplace can be secured. Platform must be stable and able
to bear the full weight of the fireplace. Platform can be constructed out of plywood, concrete, metal or any
other solid materials. Material does not have to be non-combustible.

Securing the Fireplace

The fireplace has four total nailing flanges attached to the upper and lower sides of the front of the
fireplace body. Two seismic brackets on the top of the fireplace body are also supplied with the fireplace
for added security and stabilization. The nailing flanges and seismic brackets are to be attached into a
support structure upon installation. It is crucial to the finishing that the fireplace is stable, level and plumb.
Nailing Flanges

Access Panel

An access panel is not required by the manufacturer, but it may be required by the AHJ. An access panel
is highly recommended for all Lyric fireplaces mentioned in this manual. It allows for access to the
fireplace's gas and electrical components for servicing.
Access Panel Size and Location Recommendations:
Minimum of 10"x10" in size
Located within 36" of the pilot (see "Gas Requirements and Setup" for diagram)
The size and location of the access panel may vary, but in all cases, it must allow the technician to
comfortably access and service the fireplace's gas and electrical components. These components are
attached to the pilot on a flexible gas line and can be moved to any location within 36 inches of the pilot
(which is located at the center front of the burner).
For ease of access, move the fireplace's gas and electrical components as close to the access panel as
possible. If there is any distance between the access panel and the gas and electrical components, it is
recommended to increase the size of the access panel accordingly. Prior to installation, fireplace
dealers/installers should work with their clients, project architects and/or interior designers to determine
the best size and location of their access panel.
Lyric Installation Manual: Built-in Models, April 2019
Seismic Bracket
15